GV4PE80N6 - Motor Protection Circuit Breaker (MPCB) - 40-80 A | Toggle Control to On/Off | Tesys Power | Schneider Electric

Original price was: ₹23,470.00.Current price is: ₹11,077.84.

Add to Quote
SKU: GV4PE80N6 Category:

TeSys GV motor circuit breaker, 3 poles (3P), 80A/690V, for protection of 3-phase motors 22-37kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 40-80A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

Main
Range of Product TeSys GV4
Range TeSys Deca
TeSys Deca
Device short name GV4PE
Product name TeSys GV4
TeSys Deca
Product or Component Type Motor circuit breaker
Device Application Motor protection
Trip unit technology Thermal-magnetic
Electronic
Complementary
poles description 3P
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Operating position Any position
Motor power kW 37 kW 400…415 V AC 50/60 Hz
45 kW 500 V AC 50/60 Hz
22 kW 400…415 V AC 50/60 Hz
30 kW 500 V AC 50/60 Hz
37 kW 660…690 V AC 50/60 Hz
45 kW 660…690 V AC 50/60 Hz
55 kW 660…690 V AC 50/60 Hz
30 kW 400…415 V AC 50/60 Hz
37 kW 500 V AC 50/60 Hz
Breaking capacity 100 kA Icu 220…240 V AC 50/60 Hz IEC 60947-2
50 kA Icu 380…415 V AC 50/60 Hz IEC 60947-2
50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
15 kA Icu 525 V AC 50/60 Hz IEC 60947-2
65 kA 208Y/120 V AC 50/60 Hz UL 60947
65 kA 240 V AC 50/60 Hz UL 60947
35 kA 480Y/277 V AC 50/60 Hz UL 60947
8 kA Icu 660…690 V AC 50/60 Hz IEC 60947-2
25 kA Icu 500 V AC 50/60 Hz IEC 60947-2
18 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type Toggle
Line Rated Current 80 A
Magnetic tripping current 1360 A
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current 115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Power dissipation per pole 4.6 W
Mechanical durability 40000 cycles
Electrical durability 14000 cycles AC-3 440 V In/2
7000 cycles AC-3 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous IEC 60947-4-1
Connection pitch 1.06 in (27 mm) without spreaders
1.38 in (35 mm) with spreaders
Connections – terminals Lugs-ring terminals
Tightening torque 79.66 lbf.in (9 N.m) 0.02…0.15 in² (16…95 mm²)
44.25 lbf.in (5 N.m) 0.00…0.02 in² (1.5…10 mm²)
Mechanical robustness Vibrations +/- 1 mm 2…13.2 Hz IEC 60068-2-6
Vibrations 0.7 gn 13.2…100 Hz IEC 60068-2-6
Shocks 15 gn 11 ms IEC 60068-2-27
Phase failure sensitivity Yes IEC 60947-4-1
Height 6.10 in (155 mm)
Width 3.19 in (81 mm)
Depth 4.57 in (116 mm)
Net Weight 3.20 lb(US) (1.45 kg)
color Gray RAL 7016)
Suitability for isolation Yes IEC 60947-1
Environment
Standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
Product Certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Climatic withstand IACS E10
IK degree of protection IK07 IEC 62262
Pollution degree 3
IP degree of protection IP40 IEC 60529
Ambient Air Temperature for Storage -58…185 °F (-50…85 °C)
Fire resistance 1760 °F (960 °C) IEC 60695-2-11
Operating altitude 5000 m
Ambient air temperature for operation -13…158 °F (-25…70 °C)

Additional information

Amp

40-80 A

Push Button/Rotary Handle

Toggle Control to On/Off

Model

Tesys Power

Brand

Schneider Electric

Reviews

There are no reviews yet.

Be the first to review “GV4PE80N6 - Motor Protection Circuit Breaker (MPCB) - 40-80 A | Toggle Control to On/Off | Tesys Power | Schneider Electric”