ATV340U07N4 - Variable Frequency Drives (VFD) - Heavy Duty | Altivar 340 | 1 HP / 0.75 kW | 3-Phase | Schneider Electric

Original price was: ₹72,718.00.Current price is: ₹34,322.90.

Add to Quote
SKU: ATV340U07N4 Category:

This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 0.75kW / 1hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 ?C is needed. This product integrates Modbus serial line communication protocols as standard. it weighs 1.7kg and its dimensions are, 85mm wide, 270mm high, 232.5mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and T?V certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 ?) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric?s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM). It is eco-friendly and complies with directives such as RoHS relating to environmental protection.

 

Main
Range of Product Altivar Machine ATV340
Product or Component Type Variable speed drive
Product Specific Application Machine
variant Standard version
Mounting Mode Cabinet mount
Communication Port Protocol Modbus serial
Option card Communication module, Profibus DP V1
communication module, PROFINET
communication module, DeviceNet
communication module, CANopen
communication module, EtherCAT
Phase 3 phase
Supply frequency 50…60 Hz +/- 5 %
[Us] rated supply voltage 380…480 V – 15…10 %
Nominal output current 2.2 A
Motor power kW 1.1 kW normal duty
0.75 kW heavy duty
Maximum Horse Power Rating 1.5 hp normal duty
1 hp heavy duty
EMC filter Class C3 EMC filter integrated
IP degree of protection IP20
Complementary
Discrete input number 5
Discrete input type PTI programmable as pulse input 0…30 kHz, 24 V DC 30 V)
DI1…DI5 safe torque off, 24 V DC 30 V)3.5 kOhm
programmable
number of preset speeds 16 preset speeds
Discrete output number 2.0
Discrete output type Programmable output DQ1, DQ2 30 V DC 100 mA
Analogue input number 2
Analogue input type AI1 software-configurable current 0…20 mA 250 Ohm 12 bits
AI1 software-configurable temperature probe or water level sensor
AI1 software-configurable voltage 0…10 V DC 31.5 kOhm 12 bits
AI2 software-configurable voltage – 10…10 V DC 31.5 kOhm 12 bits
Analogue output number 1
Analogue output type Software-configurable voltage AQ1 0…10 V DC 470 Ohm 10 bits
Software-configurable current AQ1 0…20 mA 500 Ohm 10 bits
Relay output number 2
Output voltage <= power supply voltage
Relay output type Relay outputs R1A
Relay outputs R1C 100000 cycles
Relay outputs R2A
Relay outputs R2C 100000 cycles
Maximum switching current Relay output R1C resistive, cos phi = 1 3 A 250 V AC
Relay output R1C resistive, cos phi = 1 3 A 30 V DC
Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2C resistive, cos phi = 1 5 A 250 V AC
Relay output R2C resistive, cos phi = 1 5 A 30 V DC
Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current Relay output R1B 5 mA 24 V DC
Relay output R2C 5 mA 24 V DC
Physical interface 2-wire RS 485
Connector Type 1 RJ45
Method of access Slave Modbus RTU
Transmission Rate 4.8 kbit/s
9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Constant torque standard
Variable torque standard
Optimized torque mode
Synchronous motor control profile Permanent magnet motor
Reluctance motor
Pollution degree 2 IEC 61800-5-1
Maximum output frequency 0.599 kHz
Acceleration and deceleration ramps S, U or customized
Linear adjustable separately from 0.01…9999 s
Motor slip compensation Can be suppressed
Not available in permanent magnet motor law
Automatic whatever the load
Adjustable
Switching frequency 2…16 kHz adjustable
14…16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 2.6 A 380 V normal duty)
2.1 A 480 V normal duty)
3.4 A 380 V heavy duty)
2.6 A 480 V heavy duty)
Line current 2.6 A 480 V without line choke heavy duty)
2.6 A 380 V with external line choke normal duty)
2.1 A 480 V with external line choke normal duty)
1.9 A 380 V with external line choke heavy duty)
1.6 A 480 V with external line choke heavy duty)
3.4 A 380 V without line choke heavy duty)
Maximum Input Current per Phase 3.4 A
Maximum output voltage 480 V
Apparent power 2.2 kVA 480 V normal duty)
2.2 kVA 480 V heavy duty)
Maximum transient current 3.1 A 60 s normal duty)
3.3 A 60 s heavy duty)
3.8 A 2 s normal duty)
4 A 2 s heavy duty)
Electrical connection Screw terminal 1.5…4 mm² line side
Screw terminal 4…6 mm² DC bus
Screw terminal 1.5…4 mm² motor
Screw terminal 0.2…2.5 mm² control
Prospective line Isc 5 kA
Base load current at high overload 2.2 A
Base load current at low overload 2.8 A
Power dissipation in W Natural convection 28 W 380 V 4 kHz heavy duty)
Forced convection 28 W 380 V 4 kHz heavy duty)
Natural convection 33 W 380 V 4 kHz normal duty)
Forced convection 33 W 380 V 4 kHz normal duty)
Electrical connection Line side screw terminal 1.5…4 mm² AWG 14…AWG 12
DC bus screw terminal 4…6 mm² AWG 12…AWG 10
Motor screw terminal 1.5…4 mm² AWG 14…AWG 12
Control screw terminal 0.2…2.5 mm² AWG 24…AWG 12
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) True
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Thermal protection motor
Safe torque off motor
Motor phase loss motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent drive
Output overcurrent between motor phase and earth drive
Output overcurrent between motor phases drive
Short-circuit between motor phase and earth drive
Short-circuit between motor phases drive
Motor phase loss drive
DC Bus overvoltage drive
Line supply overvoltage drive
Line supply undervoltage drive
Input supply loss drive
Exceeding limit speed drive
Break on the control circuit drive
Width 3.3 in (85.0 mm)
Height 10.6 in (270.0 mm)
Depth 9.2 in (232.5 mm)
Net Weight 3.7 lb(US) (1.7 kg)
Continuous output current 2.2 A 4 kHz heavy duty
2.8 A 4 kHz normal duty
Environment
Operating altitude <= 9842.52 ft (3000 m) with current derating above 1000m
Operating position Vertical +/- 10 degree
Product Certifications UL
CSA
TÜV
EAC
CTick
marking CE
Standards IEC 61800-3
IEC 61800-5-1
IEC 60721-3
IEC 61508
IEC 13849-1
UL 618000-5-1
UL 508C
Assembly style With heat sink
Electromagnetic compatibility Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation) 70 m/s² at 22 ms
Maximum acceleration under vibrational stress (during operation) 5 m/s² at 9…200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2…9 Hz
Permitted relative humidity (during operation) Class 3K5 according to EN 60721-3
Volume of cooling air 4755.2 Gal/hr(US) (18.0 m3/h)
Type of cooling Forced convection
Overvoltage category Class III
Regulation loop Adjustable PID regulator
Noise level 52.7 dB
Pollution degree 2
Ambient air transport temperature -40…158 °F (-40…70 °C)
Ambient air temperature for operation 5…122 °F (-15…50 °C) without derating vertical position)
122…140 °F (50…60 °C) with derating factor vertical position)
Ambient Air Temperature for Storage -40…158 °F (-40…70 °C)
Isolation Between power and control terminals
Ordering and shipping details
Category US1CP4B22182
Discount Schedule CP4B
GTIN 3606480966873
Returnability No
Country of origin ID

Additional information

Duty

Heavy Duty

Model

Altivar 340

HP/kW

1 HP / 0.75 kW

Phase

3-Phase

Brand

Schneider Electric

Reviews

There are no reviews yet.

Be the first to review “ATV340U07N4 - Variable Frequency Drives (VFD) - Heavy Duty | Altivar 340 | 1 HP / 0.75 kW | 3-Phase | Schneider Electric”

Your email address will not be published. Required fields are marked *