This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 0.75kW / 1hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 ?C is needed. This product integrates Modbus serial line communication protocols as standard. it weighs 1.7kg and its dimensions are, 85mm wide, 270mm high, 232.5mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and T?V certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 ?) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric?s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM). It is eco-friendly and complies with directives such as RoHS relating to environmental protection.
Range of Product | Altivar Machine ATV340 |
---|---|
Product or Component Type | Variable speed drive |
Product Specific Application | Machine |
variant | Standard version |
Mounting Mode | Cabinet mount |
Communication Port Protocol | Modbus serial |
Option card | Communication module, Profibus DP V1 communication module, PROFINET communication module, DeviceNet communication module, CANopen communication module, EtherCAT |
Phase | 3 phase |
Supply frequency | 50…60 Hz +/- 5 % |
[Us] rated supply voltage | 380…480 V – 15…10 % |
Nominal output current | 2.2 A |
Motor power kW | 1.1 kW normal duty 0.75 kW heavy duty |
Maximum Horse Power Rating | 1.5 hp normal duty 1 hp heavy duty |
EMC filter | Class C3 EMC filter integrated |
IP degree of protection | IP20 |
Discrete input number | 5 |
---|---|
Discrete input type | PTI programmable as pulse input 0…30 kHz, 24 V DC 30 V) DI1…DI5 safe torque off, 24 V DC 30 V)3.5 kOhm programmable |
number of preset speeds | 16 preset speeds |
Discrete output number | 2.0 |
Discrete output type | Programmable output DQ1, DQ2 30 V DC 100 mA |
Analogue input number | 2 |
Analogue input type | AI1 software-configurable current 0…20 mA 250 Ohm 12 bits AI1 software-configurable temperature probe or water level sensor AI1 software-configurable voltage 0…10 V DC 31.5 kOhm 12 bits AI2 software-configurable voltage – 10…10 V DC 31.5 kOhm 12 bits |
Analogue output number | 1 |
Analogue output type | Software-configurable voltage AQ1 0…10 V DC 470 Ohm 10 bits Software-configurable current AQ1 0…20 mA 500 Ohm 10 bits |
Relay output number | 2 |
Output voltage | <= power supply voltage |
Relay output type | Relay outputs R1A Relay outputs R1C 100000 cycles Relay outputs R2A Relay outputs R2C 100000 cycles |
Maximum switching current | Relay output R1C resistive, cos phi = 1 3 A 250 V AC Relay output R1C resistive, cos phi = 1 3 A 30 V DC Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC Relay output R2C resistive, cos phi = 1 5 A 250 V AC Relay output R2C resistive, cos phi = 1 5 A 30 V DC Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
Minimum switching current | Relay output R1B 5 mA 24 V DC Relay output R2C 5 mA 24 V DC |
Physical interface | 2-wire RS 485 |
Connector Type | 1 RJ45 |
Method of access | Slave Modbus RTU |
Transmission Rate | 4.8 kbit/s 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
Transmission frame | RTU |
Number of addresses | 1…247 |
Data format | 8 bits, configurable odd, even or no parity |
Type of polarization | No impedance |
4 quadrant operation possible | True |
Asynchronous motor control profile | Constant torque standard Variable torque standard Optimized torque mode |
Synchronous motor control profile | Permanent magnet motor Reluctance motor |
Pollution degree | 2 IEC 61800-5-1 |
Maximum output frequency | 0.599 kHz |
Acceleration and deceleration ramps | S, U or customized Linear adjustable separately from 0.01…9999 s |
Motor slip compensation | Can be suppressed Not available in permanent magnet motor law Automatic whatever the load Adjustable |
Switching frequency | 2…16 kHz adjustable 14…16 kHz with derating factor |
Nominal switching frequency | 4 kHz |
Braking to standstill | By DC injection |
Brake chopper integrated | True |
Line current | 2.6 A 380 V normal duty) 2.1 A 480 V normal duty) 3.4 A 380 V heavy duty) 2.6 A 480 V heavy duty) |
Line current | 2.6 A 480 V without line choke heavy duty) 2.6 A 380 V with external line choke normal duty) 2.1 A 480 V with external line choke normal duty) 1.9 A 380 V with external line choke heavy duty) 1.6 A 480 V with external line choke heavy duty) 3.4 A 380 V without line choke heavy duty) |
Maximum Input Current per Phase | 3.4 A |
Maximum output voltage | 480 V |
Apparent power | 2.2 kVA 480 V normal duty) 2.2 kVA 480 V heavy duty) |
Maximum transient current | 3.1 A 60 s normal duty) 3.3 A 60 s heavy duty) 3.8 A 2 s normal duty) 4 A 2 s heavy duty) |
Electrical connection | Screw terminal 1.5…4 mm² line side Screw terminal 4…6 mm² DC bus Screw terminal 1.5…4 mm² motor Screw terminal 0.2…2.5 mm² control |
Prospective line Isc | 5 kA |
Base load current at high overload | 2.2 A |
Base load current at low overload | 2.8 A |
Power dissipation in W | Natural convection 28 W 380 V 4 kHz heavy duty) Forced convection 28 W 380 V 4 kHz heavy duty) Natural convection 33 W 380 V 4 kHz normal duty) Forced convection 33 W 380 V 4 kHz normal duty) |
Electrical connection | Line side screw terminal 1.5…4 mm² AWG 14…AWG 12 DC bus screw terminal 4…6 mm² AWG 12…AWG 10 Motor screw terminal 1.5…4 mm² AWG 14…AWG 12 Control screw terminal 0.2…2.5 mm² AWG 24…AWG 12 |
With safety function Safely Limited Speed (SLS) | True |
With safety function Safe brake management (SBC/SBT) | True |
With safety function Safe Operating Stop (SOS) | False |
With safety function Safe Position (SP) | False |
With safety function Safe programmable logic | False |
With safety function Safe Speed Monitor (SSM) | False |
With safety function Safe Stop 1 (SS1) | True |
With sft fct Safe Stop 2 (SS2) | False |
With safety function Safe torque off (STO) | True |
With safety function Safely Limited Position (SLP) | False |
With safety function Safe Direction (SDI) | False |
Protection type | Thermal protection motor Safe torque off motor Motor phase loss motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent drive Output overcurrent between motor phase and earth drive Output overcurrent between motor phases drive Short-circuit between motor phase and earth drive Short-circuit between motor phases drive Motor phase loss drive DC Bus overvoltage drive Line supply overvoltage drive Line supply undervoltage drive Input supply loss drive Exceeding limit speed drive Break on the control circuit drive |
Width | 3.3 in (85.0 mm) |
Height | 10.6 in (270.0 mm) |
Depth | 9.2 in (232.5 mm) |
Net Weight | 3.7 lb(US) (1.7 kg) |
Continuous output current | 2.2 A 4 kHz heavy duty 2.8 A 4 kHz normal duty |
Operating altitude | <= 9842.52 ft (3000 m) with current derating above 1000m |
---|---|
Operating position | Vertical +/- 10 degree |
Product Certifications | UL CSA TÜV EAC CTick |
marking | CE |
Standards | IEC 61800-3 IEC 61800-5-1 IEC 60721-3 IEC 61508 IEC 13849-1 UL 618000-5-1 UL 508C |
Assembly style | With heat sink |
Electromagnetic compatibility | Electrostatic discharge immunity test level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5 Conducted radio-frequency immunity test level 3 IEC 61000-4-6 |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3 |
Maximum acceleration under shock impact (during operation) | 70 m/s² at 22 ms |
Maximum acceleration under vibrational stress (during operation) | 5 m/s² at 9…200 Hz |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2…9 Hz |
Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
Volume of cooling air | 4755.2 Gal/hr(US) (18.0 m3/h) |
Type of cooling | Forced convection |
Overvoltage category | Class III |
Regulation loop | Adjustable PID regulator |
Noise level | 52.7 dB |
Pollution degree | 2 |
Ambient air transport temperature | -40…158 °F (-40…70 °C) |
Ambient air temperature for operation | 5…122 °F (-15…50 °C) without derating vertical position) 122…140 °F (50…60 °C) with derating factor vertical position) |
Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
Isolation | Between power and control terminals |
Category | US1CP4B22182 |
---|---|
Discount Schedule | CP4B |
GTIN | 3606480966873 |
Returnability | No |
Country of origin | ID |