The Varlogic controllers permanently monitor the reactive power of the installation. This device also control the connection and disconnection of capacitor steps in order to obtain the targeted power factor. In case of overvoltage, low power factor or over compensation an alarm relay will activate. The user can parameter the power factor from 0.85 induct to 1. New control algorithm designed to reduce the number of switching operations and quickly attain the targeted power factor. This version include 6 step output contacts for a range of compensations. Output contacts are calibrated for 3 amps load at 250 V or 1 amp load at 400 V. The power supply allow voltage input from 320 to 460 V The dimensions of the controller are 143 mm in width, 143 mm in height, 67 mm in depth for a product weight of 800 g. Cerified for Electromagnetic Compatibility with IEC 61326, IEC 61000-6-2 and IEC 61000-6-4. A 139 mm by 139 mm swithcboard cut-out will be necessary for the flush panel mounting.

Main
Range EasyLogic
Product name EasyLogic PFC Controller
Device short name RT6
product or component type Power factor controller
Complementary
Number of step output contacts 6
[Us] rated supply voltage 320…460 V AC 50/60 Hz
Measurement current 0…5 A
Operating mode Manual
Display type 4-digit
7 segments LED
type of measurement Power factor
Alarm function 5 last alarms
input type Phase to phase
Current input CT…10000/5 A
Output type Free outputs contacts current: 1 A 400 V AC 50/60 Hz
Free outputs contacts current: 2 A 250 V AC 50/60 Hz
Free outputs contacts current: 5 A 120 V AC 50/60 Hz
Free outputs contacts current: 0.3 A 110 V DC
Free outputs contacts current: 0.6 A 60 V DC
Free outputs contacts current: 2 A 24 V DC
Type of setting Target cos phi: 0.85 inductive…1
Measurement accuracy +/- 2 %
Time delay range 10…1800 s
10…1800 s (on reconnection)
Step sequences 1.2.2.2
1.2.4.4
1.2.3.6
1.1.2.4
1.2.3.4
1.1.1.1
Linear
1.2.3.3
1.1.2.2
1.1.2.3
1.2.4.8
mounting location Panel
In cabinet
Height 143 mm
Width 143 mm
Depth 67 mm
net weight 0.8 kg
Environment
Standards EN 61010-1
IEC 61326
IEC 61010-1
IP degree of protection Rear face: IP20
Front face: IP41 conforming to IEC 60429
Ambient air temperature for operation 0…55 °C

Additional information

Steps

6

RS-485 Port

Without Port

Brand

Schneider Electric